Ravel Fire Panels/Alarms - Systems
Ravel - RE 102 / RE 104 (2 Zone and 4 Zone Fire Panel)
Ravel Fire Panels
Fire Alarm & Safety
RE 102 / RE 104
2 Zone & 4 Zone FP
- Rugged CRCA sheet with powder coated finish.
- Operates on 220v, 50Hz AC supply.
- Standby battery backup with built in charging.
- Fire / Fault status in unambiguous colored LED indication.
- Switch Mode Power Supply.
- Tactile key pad for easy panel operation.
- System on indication.
- Main, Standby status indication.
- Low Battery visual warning with audible tone.
- Relay output for actuators for Fire and Fault.
- Lamp Test facility.
- Zone wise one man Walk Test facility.
- Zone wise Isolation facility with loop voltage cut off.
- Compatible to all types of conventional detectors.
Ravel - RE 2554 / 2448 (4 Zone and 8 Zone Panels)
Ravel Fire Panels
Fire Alarm & Safety
RE 102 / RE 104
2 Zone & 4 Zone FP
- 4 Class B initiating device circuit t (IDC).
- All zones accept smoke detectors and any normally open contact device.
- Any Zone can be configured as Alarm or supervisory Zone.
- 2 Class B Notification Appliance Circuits (NAC).
- Fully complies with UL -864 and NFPA-72.
- Rugged CRCA sheet with powder coated finish.
- Operates on 120 - 220v 50 /60 Hz, AC Mains power supply.
- Standby (battery) backup 24v DC power supply with built in charger.
- 16x2 Dot Matrix LCD Display.
- Error free Fire / Fault status in unambiguous colored LED indication.
- System ON indication.
- Main, Standby status audible and visual indication.
- Battery Low visual warning with audible tone.
- Form-C relays for fire, faul t and supervisory.
- Resettable / uninterrupted 24v D.C. Output.
- RS 485 Communication facility (Optional).
- Lamp Test facility.
- Walk Test facility.
- Zone Isolation facility with loop voltage cut off.
- Earth fault annunciation facility at 0 ohm
- All field wiring circuits are Power limited except 110 - 220v AC and Battery.
- All field wiring circuits are supervised.
- AC Low voltage cutoff.
- Programmable NAC's.
- Programmable IDC's.
- Programmable Supervisory Mode.
- Programmable AC loss delay.
- Alarm verification on facility.
- Programmable Trouble reminder facility.
Ravel - RE 1504 / 1508 (Semi Addressable Panel)
Ravel Fire Panels
Fire Alarm & Safety
RE 1504 / 1508
Semi Addressable Panel
- As per NFPA-72 standards.
- Networkable / Standalone panel.
- 4 Class B conventional initiating device circuit (IDC).
- All zones accept smoke detectors and any normally open contact device.
- Any Zone can be configured as Alarm or supervisory Zone.
- Class B Notification Appliance Circuits (NAC).
- Operates on 220v 50Hz, AC Mains power supply
- Standby (battery) backup 24v DC power supply with built in charger.
- Rugged CRCA sheet with powder coated finish.
- All field wiring circuits are supervised.
- AC Low voltage cutoff.
- Programmable NAC.
- Programmable IDCs.
- Programmable AC loss delay.
- Programmable Trouble reminder.
- One Programmable Form-C relay for Fire / Fault / Supervisory.
- 2 Form-C relays for Fire.
- Alarm Verification Facility. **
- 1000 events Log with RTC.
- Error free Fire / Fault status in unambiguous colored LED indication. Main, Standby status audible and visual indication.
- Battery Low visual warning with audible tone.
- Zone Isolation Facility.
- Ground fault annunciation facility at 0 ohms.
- All field wiring circuits are Power limited except 220v A.C. and Battery.
- Peer to Peer networking Facility (up to 16 panels)
- Advanced features for the System Sensor series 300 detectors.
- 32 Detectors per Zone.
- Individual detector address with location.
- Detector maintenance Low / High alert.
- Scan active devices facility
Ravel - RE 700 (12 Zone to 128 Zone Panels)
Ravel Fire Panels
Fire Alarm & Safety
RE 700
12 Zone to 128 Zone Panels
- 12 - 128 Class B initiating device circuit (IDC / Zone Circuits).
- One Class B Notification Appliance Circuits (NAC / Sounder).
- Fully complies with IS 2189: 1988.
- Rugged CRCA sheet with powder coated finish.
- 20 X 4 LCD Dot Matrix Display.
- Low Battery / Warning audio / Visual Display.
- Operates on 220v, AC Mains power supply.
- Standby (battery) back up 24v DC power supply with built in charger
- Error free Fire / Fault status in unambiguous colored LED indication.
- Built - in DPM (Optional)
- Main, Standby status with visual/audible indication.
- Battery Low visual warning with audible tone.
- Event storage with RTC.
- Form C relays for Fire and fault.
- RS 485 and RS 232 Communication Facility.
- TCP/IP (Optional) facility.
- Walk Test facility.
- Zone Isolation facility with loop voltage cut off.
- Compatible with all types of conventional detectors, Pull Stations and any normally open contact devices.