Fire Safety Systems & Solutions - Panels, Alarm, Detectors

Ravel Fire Safety Products and Solutions

Authorised Dealer for All Telecom Products and Solutions of Panasonic Products
Provides Sales & Services to Corporates, Industries, Business Houses, Institions, Commercial Places and Home Sectors

  • - Fire Panels
  • - Smoke Detectors
  • - Your Safety
Ravel Fire Panels/Alarms - Systems

Ravel - RE 102 / RE 104 (2 Zone and 4 Zone Fire Panel)

Ravel Fire Panels
Fire Alarm & Safety
RE 102 / RE 104
2 Zone & 4 Zone FP

  • Rugged CRCA sheet with powder coated finish.
  • Operates on 220v, 50Hz AC supply.
  • Standby battery backup with built in charging.
  • Fire / Fault status in unambiguous colored LED indication.
  • Switch Mode Power Supply.
  • Tactile key pad for easy panel operation.
  • System on indication.
  • Main, Standby status indication.
  • Low Battery visual warning with audible tone.
  • Relay output for actuators for Fire and Fault.
  • Lamp Test facility.
  • Zone wise one man Walk Test facility.
  • Zone wise Isolation facility with loop voltage cut off.
  • Compatible to all types of conventional detectors.

Ravel - RE 2554 / 2448 (4 Zone and 8 Zone Panels)

Ravel Fire Panels
Fire Alarm & Safety
RE 102 / RE 104
2 Zone & 4 Zone FP

  • 4 Class B initiating device circuit t (IDC).
  • All zones accept smoke detectors and any normally open contact device.
  • Any Zone can be configured as Alarm or supervisory Zone.
  • 2 Class B Notification Appliance Circuits (NAC).
  • Fully complies with UL -864 and NFPA-72.
  • Rugged CRCA sheet with powder coated finish.
  • Operates on 120 - 220v 50 /60 Hz, AC Mains power supply.
  • Standby (battery) backup 24v DC power supply with built in charger.
  • 16x2 Dot Matrix LCD Display.
  • Error free Fire / Fault status in unambiguous colored LED indication.
  • System ON indication.
  • Main, Standby status audible and visual indication.
  • Battery Low visual warning with audible tone.
  • Form-C relays for fire, faul t and supervisory.
  • Resettable / uninterrupted 24v D.C. Output.
  • RS 485 Communication facility (Optional).
  • Lamp Test facility.
  • Walk Test facility.
  • Zone Isolation facility with loop voltage cut off.
  • Earth fault annunciation facility at 0 ohm
  • All field wiring circuits are Power limited except 110 - 220v AC and Battery.
  • All field wiring circuits are supervised.
  • AC Low voltage cutoff.
  • Programmable NAC's.
  • Programmable IDC's.
  • Programmable Supervisory Mode.
  • Programmable AC loss delay.
  • Alarm verification on facility.
  • Programmable Trouble reminder facility.

Ravel - RE 1504 / 1508 (Semi Addressable Panel)

Ravel Fire Panels
Fire Alarm & Safety
RE 1504 / 1508
Semi Addressable Panel

  • As per NFPA-72 standards.
  • Networkable / Standalone panel.
  • 4 Class B conventional initiating device circuit (IDC).
  • All zones accept smoke detectors and any normally open contact device.
  • Any Zone can be configured as Alarm or supervisory Zone.
  • Class B Notification Appliance Circuits (NAC).
  • Operates on 220v 50Hz, AC Mains power supply
  • Standby (battery) backup 24v DC power supply with built in charger.
  • Rugged CRCA sheet with powder coated finish.
  • All field wiring circuits are supervised.
  • AC Low voltage cutoff.
  • Programmable NAC.
  • Programmable IDCs.
  • Programmable AC loss delay.
  • Programmable Trouble reminder.
  • One Programmable Form-C relay for Fire / Fault / Supervisory.
  • 2 Form-C relays for Fire.
  • Alarm Verification Facility. **
  • 1000 events Log with RTC.
  • Error free Fire / Fault status in unambiguous colored LED indication. Main, Standby status audible and visual indication.
  • Battery Low visual warning with audible tone.
  • Zone Isolation Facility.
  • Ground fault annunciation facility at 0 ohms.
  • All field wiring circuits are Power limited except 220v A.C. and Battery.
  • Peer to Peer networking Facility (up to 16 panels)
  • Advanced features for the System Sensor series 300 detectors.
  • 32 Detectors per Zone.
  • Individual detector address with location.
  • Detector maintenance Low / High alert.
  • Scan active devices facility

Ravel - RE 700 (12 Zone to 128 Zone Panels)

Ravel Fire Panels
Fire Alarm & Safety
RE 700
12 Zone to 128 Zone Panels

  • 12 - 128 Class B initiating device circuit (IDC / Zone Circuits).
  • One Class B Notification Appliance Circuits (NAC / Sounder).
  • Fully complies with IS 2189: 1988.
  • Rugged CRCA sheet with powder coated finish.
  • 20 X 4 LCD Dot Matrix Display.
  • Low Battery / Warning audio / Visual Display.
  • Operates on 220v, AC Mains power supply.
  • Standby (battery) back up 24v DC power supply with built in charger
  • Error free Fire / Fault status in unambiguous colored LED indication.
  • Built - in DPM (Optional)
  • Main, Standby status with visual/audible indication.
  • Battery Low visual warning with audible tone.
  • Event storage with RTC.
  • Form C relays for Fire and fault.
  • RS 485 and RS 232 Communication Facility.
  • TCP/IP (Optional) facility.
  • Walk Test facility.
  • Zone Isolation facility with loop voltage cut off.
  • Compatible with all types of conventional detectors, Pull Stations and any normally open contact devices.